Features and Specs
Features¶
- Real-Time Vibration and Tilt Monitoring
- Optional Class I Microphone
- Complete Wireless Solution
- Easy to Install
- Remote Management and Configuration
- Peak Particle Velocity Histogram Recording
- Pitch and Roll Recording
- Event Monitoring with Pre-Trigger Recording
- Integrated 4G LTE Cellular Communications
- 2.5GHz Wifi Communitions
- Event notification
- Battery or USB Power
- Device configuration and diagnostics via USB
- Device configuration via FTP or API
- FTP or HTTP uploading of event and histogram data
- MQTT remote configuraton and real-time data telemetry
- Over-the-air software updates
Specifications¶
Vibration Specifications | Veva III | Veva III - 02 Veva III - 03 Veva III - E01 Veva III - W01 |
---|---|---|
Measurement Axes | 3 | 3 |
Frequency Response | 1 - 1000 Hz | 1 - 1000 Hz |
Max. Velocity Ranges | 1.2 in/s (31 mm/s) @ 100Hz 2.5 in/s (62 mm/s) @ 100Hz 4.9 in/s (125 mm/s) @ 100Hz (See Maximum Measurable Velocity Curves below.) | 1.2 in/s (31 mm/s) @ 100Hz 2.5 in/s (62 mm/s) @ 100Hz 4.9 in/s (125 mm/s) @ 100Hz (See Maximum Measurable Velocity Curves below.) |
Accuracy | ± 5% | ± 5% |
Sample Rates | 1, 2 and 4 kHz | 1, 2 and 4 kHz |
Time stamp Resolution | 1 ms | 1 ms |
Data Outputs | Peak Amplitude (mm/s or in/s) Peak Frequency (Hz) Peak Particle Velocity (mm/s or in/s) Peak Vector Sum (mm/s or in/s) Raw Acceleration Data (g or mm/s2) Zero Crossing Frequency (Hz) | Peak Amplitude (mm/s or in/s) Peak Frequency (Hz) Peak Particle Velocity (mm/s or in/s) Peak Vector Sum (mm/s or in/s) Raw Acceleration Data (g or mm/s2) Zero Crossing Frequency (Hz) |
Acceleration Ranges | ± 2, 4 and 8 G | ± 2, 4 and 8 G |
Alert Threshold Range | 0.04 to 4.9 in/s (1 to 125 mm/s) | 0.04 to 24.4 in/s (1 to 620 mm/s) |
Filtering Standards | ISEE DIN 4150 BS 7385 AS 2187 ONORM S 9012 ISO 8569 IN 1226 NS 8176 NS8141 SS 4604866 SS 025211 SS 4604861 | ISEE DIN 4150 BS 7385 AS 2187 ONORM S 9012 ISO 8569 IN 1226 NS 8176 NS 8141 SS 4604866 SS 025211 SS 4604861 |
Tilt Specifications | Veva III (all versions) |
---|---|
Measurement Axes | 2 |
Range (Pitch and Roll) | ± 90° |
Accuracy | ± 0.005° |
Resolution | 0.0035° |
Time stamp Resolution | 0.1 ms |
Temperature Stability | ± 0.5°C (-45° to 110°C) ± 0.09°F (-49° to 230°F) |
Stabilization Time | 10 secs |
Alert Thresholds | 0.5° to 70.0° |
Data Outputs | Pitch and Roll base values Pitch and Roll current values Pitch and Roll differential values |
Reading Interval | 10 seconds to 12 hours |
Sound Level Specifications (microphone required) | Veva 3-E01 Veva 3-W01 |
---|---|
Type | IEC61672 Class 1 |
Weightings | A, C, and Z |
Sample Rate | 48kHz |
Frequency Response | 20 Hz - 20 kHz |
Acoustic Overload | 120dB |
Distortion | 2.2% at 115dB SPL |
Equalization | Flat, 10 Hz to 20 kHz |
Communications Specifications | Veva 3 Veva 3-02 Veva 3-03 | Veva 3-E01 Veva 3-W01 |
---|---|---|
Cellular Type | 4G LTE M1/NB1/EGPRS | 4G LTE M1/NB1/EGPRS |
LTE Frequency Bands | 1,2,3,4,5,8,12,13,18,19,20,25,28,39 | 1,2,3,4,5,8,12,13,18,19,20,25,28,39 |
EGPRS Frequency Bands | 850/900/1800/1900MHz | 850/900/1800/1900MHz |
Cellular Antenna Requirements | VSWR < 2 Input Impedance: 50Ω Efficiency: > 30% Max Input Power: 50W Cable Insertion Loss: < 1dB (LTE B5/B8/B12/B13/B18/B19/B20/B26/B28) Cable Insertion Loss: < 1.5dB (LTE B1/B2/B3/B4/B25/B39) | VSWR < 2 Input Impedance: 50Ω Efficiency: > 30% Max Input Power: 50W Cable Insertion Loss: < 1dB (LTE B5/B8/B12/B13/B18/B19/B20/B26/B28) Cable Insertion Loss: < 1.5dB (LTE B1/B2/B3/B4/B25/B39) |
WiFi Type (W01 Models) | 802.11 b/g | |
WiFi Frequency (W01 Models) | 2.4GHz | |
WiFi Tramission Rate (W01 Models) | 1 - 11Mbps (802.11b); 6 - 54Mbps (802.11g) | |
Protocols | FTP, M2M/SMS, NTP, HTTP | FTP, M2M/SMS, NTP, HTTP, MQTT |
Power and Environmental | Veva 3 Veva 3-02 Veva 3-03 | Veva 3-E01 Veva 3-W01 |
---|---|---|
Battery | 4 x D-cell Li-SOCl2 | 4 x D-cell Li-SOCl2 |
Battery Capacity | 52Ah | 52Ah |
Battery Life | up to 1 year, depending on configuration and environmental factors. | 6 - 8 months, depending on configuration and environmental factors. |
Line Power | 5V D.C. via USB, 2A USB adapter required. | 5V D.C. via USB, 2A USB adapter required. 7 - 18V D.C. Special cable required. |
Operating Temperature | -40°F to +185°F (-40°C to +85°C) | -40°F to +185°F (-40°C to +85°C) |
Physical | Veva 3 | Veva 3-02 Veva 3-03 | Veva 3-E01 Veva 3-W01 |
---|---|---|---|
Enclosure | Aluminum, IP67 rated | Aluminum, IP67 rated | Aluminum, IP67 rated |
Dimensions | 6.0in. x 1.6in. x 3.9in. (152mm x 41mm x 98mm) | 6.0in. x 1.6in. x 3.9in. (152mm x 41mm x 98mm) | 6.0in. x 1.6in. x 3.9in. (152mm x 41mm x 98mm) |
Weight | 2.5lbs. (1.15kg) w/4 D-cell batteries | 2.5lbs. (1.15kg) w/4 D-cell batteries | 2.5lbs. (1.15kg) w/4 D-cell batteries |
Mounting | 5/16in. (M8) through-hole | ⅜in. (M10) through-hole | ⅜in. (M10) through-hole |
Connectors | Micro USB and RP-SMA Female Antenna | Micro USB and RP-SMA Female Antenna | RP-SMA Female Antenna (Cellular/Wifi, GPS, BLE) 6-pin LEMO (USB) 4-pin LEMO (Auxiliary) |
General | Veva 3 Veva 3-02 Veva 3-03 | Veva 3-E01 Veva 3-W01 |
---|---|---|
Data Storage | 2 Gb Micro SD Card | 512Mb Micro SD Card, expandable to 2Gb |
Data Buffer | 1 Mb | 1 Mb |
Clock | Network Time Sync, NTP | Network Time Sync, NTP |
Data Output Format | CSV, JSON | CSV, JSON |
Firmware Updates | Remote over-the-air programming (OTAP) | Remote over-the-air programming (OTAP) |
Device Management | FTP, API or USB terminal | FTP, API or USB terminal |
Last update: March 8, 2024